Dmg Silagum Comfort Starter Kit

Denture Relining Material

Features

  • Brand : DMG
  • Model : Denture Relining Material
  • Dmg Silagum Comfort Starter Kit : Denture Relining Material

    Dmg Silagum Comfort Starter Kit - 1 Unit

    $ 130.00

    Sold Out Email :

    The Dentist Shop Assurance

    • Brand New
    • Secure Payment
    • 100% Genuine Products
    • Manufacturer Warranty

Description

FEATURES

  • Impressions can be stored for a long time
  • Excellent recovery after deformation
  • Good hydrophilicity
  • High-contrast shades
  • Tailored to all dental requirements

DESCRIPTION

 

Silagum has been known for years as a proven and reliable impression material based on VPS.

Each single product of the Silagum line is characterized by its exceptional material properties and ease of use.

Silagum’s hydrophilicity and thus improved wettability yields a pinsharp reproduction of subgingival areas.

From Handmix over automatically mixing to fully automatic mixing with the MixStar system, products are available in a wide variety of application forms. Silagum offers the right solution for any technique and use.

Excellent recovery after deformation

Due to its high elasticity, Silagum exhibits a very good recovery after deformation, i.e. an extremely low compression set.

It is also this high elasticity that makes removal from the mouth so easy. Any deformation that occurs upon removal safely recovers, thus ensuring precise dimensional reproduction.

Very good hydrophilicity

Thanks to its high surface wettability, Silagum provides optimum adaptation to the tooth substance and mucous membrane in the moist oral environment.
Together with the highly flowable viscosity, this enables precise reproduction of subgingival areas. This results in pinsharp impressions, even of the finest details*.

 

COMPOSITION:

Composition Addition-cured vinyl polysiloxanes, hydrogen polysiloxanes, fillers, pigments, additives, platinum catalyst

 

INDICATION:

Relining material for total, partial and implant-supported dentures

KEY SPECIFICATION

TECHNICAL DATA:

                                Silagum Comfort     Silagum Varnish

Application time*    1.45mins                    2mins

Setting time in mouth    6 min                   

Setting (curing) time*   15 min                  15 min

Evaporation time           

Disinfection of the Automix-Dispenser

The Automix-Dispenser and the trimmer and brush holders can be reused after disinfection and sterilization, but should be replaced if there are visible signs of wear (e.g. scratches). The device can be disinfected and sterilized using a commercially available immersion disinfection solution. DMG recommends using only RKI (Robert Koch Institute) listed disinfection solutions. The Automix-Dispenser is also autoclavable

Storage and Shelf Life 

Store in a dry space at normal room temperature (15 – 25 °C / 59 – 77 °F)

Do not store in the refrigerator or freezer

Keep out of direct sunlight

Leave used mixing tips on the cartridge after use. They serve as a cap

Do not use past the expiration date

PACKAGING

DMG Silagum Comfort Starter Kit:

  • 1 x 50ml cartiridge with 4 automix tips
  • 1 x 5 ml Bottle Primer
  • 2 x 10 ml Bottle Varnish

DIRECTION TO USE

Direct relining in the patient’s mouth

1. If necessary, remove old permanently soft relining material.

2. Trim off a minimum of 1 mm of all the areas needing to be relined. DMG recommends a rounded preparation of the edges of the dentures.

Note: Following this preparation, protect the denture surface from moisture, saliva, and monomer-containing resins.

3. Apply an even layer of primer (Silagum-Comfort Primer) in accordance with the manufacturer’s information and let the solvent evaporate completely (approx. 1 minute). Be sure to completely cover the ridges and edge areas. Apply at least two coats

4. Apply Silagum-Comfort first on the ridges and edges of the denture and then on the base of the denture. The layers should be at least 2 mm thick

5. Remove saliva with a suction instrument.

Caution!

Uncured silicone can trigger the patient’s gag reflex.

Therefore, to prevent the silicone from entering the patient’s throat and esophagus, be sure that the patient is sitting upright and slightly bent forward when performing any functional movements.

6. Insert the denture into the patient’s mouth within the specified application time and instruct the patient to bite into normal occlusion. Have the patient perform gentle swallowing and chewing movements (without exerting excessive pressure) for 5 minutes with his or her mouth closed

7. Remove the denture from the mouth after approximately 6 minutes and let it harden

8. Clean and disinfect the denture. Note: If needed, carefully align the dry and grease-free relining by applying and modeling additional Silagum-Comfort. Let it set in the patient’s mouth for 7 minutes or in a pressure pot (40 – 50 °C) for 5 minutes

9. Remove excess material with sharp scissors or a scalpel. Smooth the trimmed edges with a suitable silicone trimmer

10. Using a brush, apply the Silagum-Comfort Varnish to the treated areas in accordance with the manufacturer’s instructions, avoiding air bubbles as much as possible, and then let dry.

Indirect relining at the laboratory

1. Following a functional impression, the gypsum is poured into the denture on the jaw side and mounted on a relining jig. Note: Do not use polyether as the impression material. The impression material used should have a long application time and appropriate viscosity. DMG recommends applying a suitable separating medium (gypsum against resin)

2. Produce a negative by pouring the occlusal part of the denture or rows of teeth, which must be firmly fixed in its vertical relationship to the model. For this purpose, DMG recommends using a special relining device that facilitates the exact repositioning of model and negative (cuvette)

3. Remove impression material

4. Trim the denture surface on the jaw side at least 1 mm and clean it. Note: Following this preparation, protect the denture surface from moisture and monomer-containing resins

5. Apply an even layer of primer (Silagum-Comfort Primer) in accordance with the manufacturer’s information and let the solvent evaporate completely (approx. 1 minute). Be sure to completely cover the ridges and edge areas. Apply at least two coats

6. Apply Silagum-Comfort first on the ridges and edges of the denture and then on the base of the denture. The layers should be at least 2 mm thick

7. Reposition the denture on the model, and use the cuvette to completely envelop the negative

8. Let the material set and harden for 10 minutes in the pressure pot at 40 – 50 °C. Note: If needed, carefully align the dry and grease-free relining by applying and modeling additional Silagum-Comfort. Let it set in the pressure pot for 5 minutes (40 – 50 °C)

9. Remove excess material with sharp scissors or a scalpel. Smooth the trimmed edges with a suitable silicone trimmer

10. Using a brush, apply the Silagum-Comfort Varnish to the treated areas in accordance with the manufacturer’s instructions, avoiding air bubbles as much as possible, and then let dry.

 

Brand
DMG
Model
Denture Relining Material
Dmg Silagum Comfort Starter Kit
Denture Relining Material

Average user rating

0.0/ 5


Related Products

Your cart has Updated